{"id":737,"date":"2010-01-29T16:32:17","date_gmt":"2010-01-29T11:32:17","guid":{"rendered":"http:\/\/greenspaces.in\/blog\/?p=737"},"modified":"2010-02-04T13:56:42","modified_gmt":"2010-02-04T08:56:42","slug":"energy-management","status":"publish","type":"post","link":"https:\/\/greenspaces.in\/blog\/energy-management\/","title":{"rendered":"Energy Management"},"content":{"rendered":"<h2><strong><span style=\"color: #ff6600;\">Best Practices: Energy Management<\/span><\/strong><\/h2>\n<p>In Energy management we follow certain practices that help us in reducing our electricity bills without affecting the quality of life. We have benefitted from these practices; our results show maximum 30% reduction in our electricity bills. These practices can be further improved upon.<\/p>\n<p>We at Paharpur Business Centre follow these best practices in energy management<\/p>\n<ul>\n<li>Instead of GLS lamps, we use PL lights, which are      plug in CFL lamps, they use compact fluorescent (CFL) technology meaning      they are efficient and less costly to replace.<\/li>\n<li>All fluorescent lights in our office are Philips      trulite which are BEE 5 star rated with electronic ballast.<\/li>\n<li>Motion sensors are used to switch off lights in      unoccupied common areas.<\/li>\n<li>All our displays are energy efficient LCDs\/Plasma to      save on energy.<\/li>\n<li>Energy consumption is monitored and analyzed on daily      basis.<\/li>\n<li>Green mesh &amp; heat reflective film has been put on      the south wesh side of the building to block the direct sun heat into the      building.<\/li>\n<li>High albedo paint has been put on the building      envelope to reduce the indirect heat gain into the building.<\/li>\n<li>The heat gain into the building from the rooftop is      minimum because of green house.<\/li>\n<li>Use of\u00a0 five      star rated equipments especially air conditioners.<\/li>\n<li>High Efficiency Super Diesel is used for all DG sets      to reduce pollution.<\/li>\n<li>Diesel is centrifuged to clean it before use in the Generators.<\/li>\n<li>Energy consumption is monitored and analyzed on daily      basis on a BAS system<\/li>\n<li>Green mesh &amp; heat reflective film is put on the      south west side windows of the building to block the direct sun heat into      the building.<\/li>\n<li>High albedo paint has been put on the building      envelope to reduce the indirect heat gain into the building.<\/li>\n<li>The heat gain into the building from the rooftop is      minimum because of green house that has been created on the roof.<\/li>\n<\/ul>\n<p><strong><span style=\"color: #ff6600;\">Energy Saving Features of our HVAC System<\/span><\/strong><\/p>\n<ul>\n<li>Chiller has a COP of 6.15; it\u2019s an efficient 212 TR      water cooled screw chiller from Trane.<\/li>\n<li>Two way valve regulate the chilled water inlet into      the AHU coil as per the heat load.<\/li>\n<li>CO2 sensors have been put to regulate the fresh air      inlet inside the air conditioned space. Its demand controlled ventilation.<\/li>\n<li>New Pumps and all AHU motors are VFD controlled.<\/li>\n<li>UVC light have been installed on the AHU cooling      coils to keep the air &amp; coil clean of indoor air contaminants.<\/li>\n<li>The new system has VAV in air circuits to regulate      the air supply as per heat load.<\/li>\n<li>New Double skin AHU help reduce the leakage &amp;      noise.<\/li>\n<li>Heat Recovery wheel unit ensures that incoming fresh      air is precooled before it is let in into the system<\/li>\n<li>Complete system is managed centrally through BMS<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Best Practices: Energy Management In Energy management we follow certain practices that help us in reducing our electricity bills without affecting the quality of life. We have benefitted from these practices; our results show maximum 30% reduction in our electricity bills. These practices can be further improved upon. We at Paharpur Business Centre follow these [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[43],"tags":[22,19,40,41,34,37],"_links":{"self":[{"href":"https:\/\/greenspaces.in\/blog\/wp-json\/wp\/v2\/posts\/737"}],"collection":[{"href":"https:\/\/greenspaces.in\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/greenspaces.in\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/greenspaces.in\/blog\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/greenspaces.in\/blog\/wp-json\/wp\/v2\/comments?post=737"}],"version-history":[{"count":5,"href":"https:\/\/greenspaces.in\/blog\/wp-json\/wp\/v2\/posts\/737\/revisions"}],"predecessor-version":[{"id":767,"href":"https:\/\/greenspaces.in\/blog\/wp-json\/wp\/v2\/posts\/737\/revisions\/767"}],"wp:attachment":[{"href":"https:\/\/greenspaces.in\/blog\/wp-json\/wp\/v2\/media?parent=737"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/greenspaces.in\/blog\/wp-json\/wp\/v2\/categories?post=737"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/greenspaces.in\/blog\/wp-json\/wp\/v2\/tags?post=737"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}